DocsEmissary-ingress
3.5
Statistics and monitoring
Statistics and monitoring
Emissary-ingress collects many statistics internally, and makes it easy to direct this information to a statistics and monitoring tool of your choice.
As an example, here are some interesting statistics to investigate:
upstream_rq_totalis the total number of requests that a particular service has received via Emissary-ingress. The rate of change of this value is one basic measure of service utilization, i.e. requests per second.upstream_rq_xxis the total number of requests to which a service responded with a given status code. This value divided by the prior one, taken on a rolling window basis, represents the recent response rate of the service. There are corresponding classes for2xx,3xx,4xxand5xxcounters that can help clarify the nature of responses.upstream_rq_timeis a Prometheus histogram or StatsD timer that tracks the latency in milliseconds of a given service from Emissary-ingress's perspective.
Overriding Statistics Names
The optional stats_name element of every CRD that references a service (Mapping, TCPMapping,
AuthService, LogService, RateLimitService, and TracingService) can override the name under which cluster statistics
are logged (usersvc above). If not set, the default is the service value, with non-alphanumeric characters replaced by
underscores:
service: foowill just usefooservice: foo:8080will usefoo_8080service: http://foo:8080will usehttp___foo_8080service: foo.othernamespacewill usefoo_othernamespace
The last example is worth special mention: a resource in a different namespace than the one in which Emissary-ingress is running will automatically be qualified with the namespace of the resource itself. So, for example, if Emissary-ingress is running in the ambassador namespace, and this Mapping is present in the default namespace:
then the service will be qualified to default-service.default, so the stats_name will be default_service_default rather than simply default_service. To change this behavior, set stats_name explicitly.
Monitoring Statistics
There are several ways to get different statistics out of Emissary-ingress:
- The
:8877/metricsendpoint can be polled for aggregated statistics (in a Prometheus-compatible format). This is our recommended method as both Envoy metrics and Emissary-ingress control plane metrics are collected. - Emissary-ingress can push Envoy statistics over the StatsD or DogStatsD protocol.
The Four Golden Signals
The Four Golden Signals are four generally-accepted metrics that are important to monitor for good information about service health:
Latency
The time it takes to service a request as a histogram of time taken by individual requests, which can be an effective latency metric.
In StatsD, this stat would be expressed as cluster.$name.upstream_rq_time.
While in Prometheus format, this metric would be expressed as envoy_cluster_upstream_rq_time_bucket{envoy_cluster_name="$name"}.
Traffic
The amount of demand being placed on your system as a gauge that shows the number of active outstanding requests, which can be a good proxy for traffic.
In StatsD, this stat would be expressed as cluster.$name.upstream_rq_active.
While in Prometheus format, this metric would be expressed as envoy_cluster_upstream_rq_active{envoy_cluster_name="$name"}.
Errors
The number of failing requests. Some errors (e.g. a request succeeds, but gives the wrong answer) can only be detected by application-specific monitoring; however, many errors can be spotted simply by looking at the HTTP status code of requests. Monitoring it over time can show error rates.
In StatsD, cluster.$name.upstream_rq_5xx is a counter of HTTP 5xx responses.
While in Prometheus, envoy_cluster_upstream_rq_xx{envoy_response_code_class="5", envoy_cluster_name="$name"} is a counter of HTTP 5xx responses.
Saturation
The hardest metric to measure, saturation describes how much of the total capability of the system to respond to requests is being used. Fully measuring saturation often requires application-specific monitoring, but looking at the 99th percentile of latency over a short window - perhaps a minute - can often give an early indication of saturation problems.